CAPTIN 1000BW

CAPTIN 1000BW  Site energy and management solution
CAPTIN 1000BW  Site energy and management solution
CAPTIN 1000BW  Site energy and management solution
CAPTIN 1000BW  Site energy and management solution
CAPTIN 1000BW  Site energy and management solution
CAPTIN 1000BW  Site energy and management solution

Site energy and management solution

  • Integrated site management and power feeding
  • Up to 4000W output power
  • 10 protected outputs, modular distribution
  • Battery backup connections (2) and management
  • Very easy integration in TNM systems
  • Full open interface, ETSI ES 202 336 compliant
  • Optional A + B feed (Dual AC input)

The CAPTIN is a total solution designed specifically for use in access network outdoor cabinets and shelter, integrating power supply and management, environmental management, access control and more. Designed in close cooperation with market leading access network operators, it combines redundant power back-up with almost unlimited capabilities for monitoring and control of infrastructure all in a single chassis. Remote communication over IP is provided without the need for any proprietary application or software.

The integration and optimization of site, security and energy management functions into a single power system brings significant savings in terms of module optimization and cabinet cabling. Furthermore, the compact size of the system (280mm deep x 19’’/ETSI wide x 2U (88mm) high) allows a reduction of overall cabinet size when compared to earlier solutions. The modular construction enables progressive investment by installing optional modules in the field at any time.

Reducing the OPEX of our customers is a major objective in the design of Alpha Innovations solutions. Remote monitoring and control of all variables provides advanced knowledge of system status reducing the occurrences of unnecessary site visits. The capabilities of the CAPTIN system far exceed this, supporting additional functions such as statistical data recording and analysis, energy consumption reduction and automatic testing routines - all aimed at reducing network operating expenses.

The integral control module features SNMP and XML standard open architecture. IP based services enable fast and easy transmission of information directly to the appropriate people (security, power, access, etc) as required by the operational organisation of the network.

This solution can be configured to support NiMh batteries from ARTS Energy.

 

Electrical
Input Voltage:
90 to 265Vac
Input Frequency:
47 to 63Hz
Input Current:
28A max (option input A&B - 2x14A max)
Efficiency:
Module up to 95% (ECOR1048TN)
Output Voltage:
-40.5 to -58Vdc (0V conn. to protective Earth)
Output Power:
4000W max (4x 1000W)
Output Load Current (with breaker):
4x30A + 6x10A
Battery Current Breaker:
2x60A
Features
LVD circuit + Reverse polarity protection
 
Battery simmetry check
 
Auxiliary Output 12V-1A:
with SAM0948
Alarms:
4 digital outputs (realays - NO/NC)
2 free digitals inputs
 
2 digital inputs used for breaker monitoring (Loads, Bat)
 
Mechanical
Dimensions:
 
mm:
87H (2U) x 440W x 280D
inches:
3.5H x 17.3W x 11D
Mounting:
19" or ETSI
Weight:
 
Shelf:
6.15kg (13.56lb)
Rectifier:
1.16kg (2.56lb)
Connections (rear side)
 
Load (protected by breakers):
 
4 Positions:
Spring cage terminal block (4 to 6 mm²)
6 Positions:
Spring cage terminal block (1 to 1.5 mm²)
Auxiliary 12Vdc output (available with SAM0948 card only):
Spring cage terminal block (1 to 1.5 mm²)
 
Battery:
Terminal block (0.5 to 10 mm²)
AC Input:
Terminal block (0.5 to 4 mm²)
Alarms:
Female Sub 15D
Connections (front side)
 
CAN communication:
Modular RJ45 connector (8P8C)
Site Management (Optional):
See specifications sheet
Environmental
Temperature:
 
Standard:
-20 to 55°C (-4 to 131°F)
Extended (derated output power):
-40 to 70°C (-40 to 158°F)
Storage:
-40 to 85°C (-40 to 185°F)
Humidity:
 
Operating:
20 to 80% RH non-condensing
Storage:
10 to 95% RH non-condensing
Elevation:
Up to 2000m (6562ft)
Cooling:
Fan cooled (front to rear)
Standards
Safety:
CE marked
 
EN60950-1 (CEBEC-SGS marked)
Insulation:
Input-Output:
4242Vdc; Input-Earth:
min 2121Vdc
Environment:
RoHS compliant
EMC:
see module ECOR1048TN
Immunity:
EN61000-4-3 (radiated immunity)
 
EN61000-4.2 (ESD)
 
EN61000-4-6 (conducted immunity)
 
EN61000-4-4 (Burst)
 
EN61000-4-5 (Surge immunity)
 
EN61000-4-11 (Voltage Dips and interrupts)
Emission:
EN55022 (conducted level B)
 
EN55022 (radiated level B)
 
EN61000-3-2 (Harmonic current)
EN61000-3-3 (Voltage fluctuations and flicker)

Standard Part Numbers
  • 9400 003 00051: CAPTIN1000BW STD1 MCU PRO 0.5U SAM READY
  • 9400 003 00052: CAPTIN1000BW STD2 MCU PRO LCD
Related Items
  • Connectors & cables:
  • Converter DC/DC:
  • Distribution:
    • 5304 500 00971: Kit of 40 breakers 2.5A long delay IEG1-1-52-2.5-A-01-V
    • 5304 500 01041: Kit of 40 breakers 6A long delay IEG1-1-52-6.0-A-01-V
    • 5304 500 01051: Kit of 40 breakers 10A long delay IEG1-1-52-10.0-A-01-V
    • 5304 500 01061: Kit of 40 breakers 30A long delay IEG1-1-52-30.0-A-01-V
  • Filler:
  • Mechanical:
  • Monitoring & Control:
    • ADIO DIN 17: Extension Module for measuring 10 temperatures (NTC)
    • MCU0948M4: 1U high Controller for 850W/1000W systems dry alarm only (no comp@s card)
    • MCU0948M4LP: 0,5U high Controller for 850W/1000W systems dry alarms only (no comp@s). Call factory for part number with comp@s
    • SAM0948: SITE & ACCESS management card
  • Rectifier Module:
  • Sensors & Actuators:
  • Shelf:
    • 4004 112 83241: Empty shelf including distribution with ten breakers (4*30A; 6*10A) 19inch 1 mains input
  • Solution: