Monitoring Control Unit with OLED Display

The MCU0x48M4-OLED is a microcontroller-based monitoring system designed for telecommunications power systems using 300W and 1000W rectifiers. It enables the monitoring and control of up to 4 rectifiers (up to 9 when integrated with the COMPAS platform), one battery string, and power distribution within a 1U to 2U power shelf, depending on the number of rectifiers installed.

This controller is a hot-pluggable, hot-swappable unit that fits into a 1U slot alongside the rectifier modules. It integrates COMPAS, providing advanced monitoring capabilities via Ethernet or USB.

Additionally, it supports interoperability with CAN bus-connected peripherals and equipment, such as cabinet security systems and environmental management devices.

Highlights

  • Monitors up to 4 rectifiers — scalable to 9 when integrated with the COMPAS platform
  • Hot-pluggable, hot-swappable — fits into a 1U slot alongside rectifier modules, no downtime for replacement
  • OLED front display — shows output voltage, battery charge current, rectifier current, IP address, relay status, and LVD status directly on the unit
  • Battery management — current limitation, temperature compensation, battery test, and capacity estimation
  • Wide operating range — -40°C to 70°C, suited for outdoor and harsh cabinet environments
  • Flexible connectivity — Ethernet, USB, and CAN bus, with configurable DIP switches for different rectifier module compatibility (ECOR0348TN, ECOR1048TN, or CDCWI1048TN)
  • Customizable — specific configuration, Python scripting, and specific alarming when needed

Datasheet

  • Input:
    • Input DC Voltage: 48Vdc (-15%, +20%)
    • Starting Voltage: 36V
    • Source Power: 15W max
  • Output (USB-A):
    • Voltage: 5V (±0.25V)
    • Current, nominal: 500mA
    • Current, max: 600mA
  • Communication Interface:
    • Ethernet 10/100 Mbit
    • USB PC
    • USB-A for extra devices
    • CAN
  • 4 Relays (digital output): max 60VDC (42VAC), max 1A per contact
  • Digital Inputs: 4 digital inputs for external dry contacts monitoring
  • Dimensions: 85.9mm x 217.3mm x 40.7mm (1U)
  • Weight: 200g
  • Controller I/O:
    • DC bus voltage
    • Battery current
    • Battery temperature
    • Rectifier status
    • 4 digital inputs
    • 4 potential-free relays (NO/NC)
  • Battery Management:
    • Current limitation
    • Temperature compensation
    • Battery test
    • Capacity estimation
  • Customization:
    • Specific configuration
    • Python scripting
    • Specific alarming
  • OLED Screen
    • Information displayed: output voltage, battery charge current, rectifier current, IP address, relay status, LVD status
    • MCU status LED:
      • Green steady: MCU is OK
      • Green, quick blinking (200ms): MCU is starting, no software present, or CAN bus issue
      • Green, slow blinking (1s): testing batteries
      • Green steady, brief blackout (200ms): boost mode
    • LVD status LED: green shining = LVD closed
    • Alarm status LED: red shining = alarm active
  • Configuration
    • Switch PIN 1: OFF = configuration with ECOR0348TN (300W) modules · ON = configuration with ECOR1048TN or CDCWI1048TN modules
    • Switch PIN 2: OFF = normal configuration · ON = BEZEQ configuration
    • Switch PIN 3: not used, OFF by default
  • Operating Temperature: -40 to 70°C
  • Humidity, Operating: 20 to 80% RH non-condensing
  • Humidity, Operating (optional): up to 95% with coating
  • Humidity, Storage: 10 to 95% RH non-condensing
  • Safety:
    • CEBEC markings
    • IEC 62368-1
    • IEC 62368-3 (USB power)
  • Environment: RoHS compliant
  • EMC (inside related shelves):
    • EN 61000-6-1
    • ETSI EN300386
    • EN 61000-6-3
  • Global Approvals:
    • CE and CEBEC marked
    • US and CAN checked
  • 9413 060 10161: Monitoring Control Unit, 1U height, with OLED screen
  • 9413 060 10171: Monitoring Control Unit, 0.5U height, no screen

FAQ

It's a monitoring and control unit for telecom power systems, managing up to 4 rectifiers (up to 9 with COMPAS), a battery string, and power distribution in a 1U or 2U shelf, such as the ACE102, ACE104, CAPTIN 1000BW, or CAPTIN 300FA.

It displays output voltage, battery charge current, rectifier current, the unit's IP address, relay status, and LVD (low voltage disconnect) status, directly on the front panel without needing a separate monitoring session.

Yes. It's a hot-pluggable, hot-swappable unit that fits into a 1U slot alongside the rectifier modules, so it can be replaced without interrupting power to the load.

Request a quote